Heatiator Heatilator Wood Burning Fireplace CL36D Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Grelhadores Heatiator Heatilator Wood Burning Fireplace CL36D. Heatiator Heatilator Wood Burning Fireplace CL36D User Manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
1
Owners Manual
Installation and Operation
Models:
CL36D
CR36D
Wood Burning Fireplace
Installation and service of this  replace
should be performed by quali ed personnel.
Hearth & Home Technologies suggests NFI
certi ed or factory-trained professionals, or
technicians supervised by an
NFI certi ed professional.
Fire Risk
For use with solid wood fuel or decorative
gas appliance only.
DO NOT install unvented gas logs.
WARNING
If the information in these instruc-
tions is not followed exactly, a
re may result causing property
damage, personal injury, or death.
Do not store or use gasoline or other  am-
mable vapors and liquids in the vicinity of
this or any other appliance.
Do not over re. Over ring will void your
warranty.
Comply with all minimum clearances to
combustibles as speci ed. Failure to
comply may cause house  re.
WARNING
WARNING
Hot screen/mesh and glass doors will cause burns.
DO NOT touch screen/mesh or glass doors until
cooled
NEVER allow children to touch screen/mesh or glass
doors
Keep children away
CAREFULLY SUPERVISE children in same room as
replace.
Alert children and adults to hazards of high
temperatures.
High temperatures may ignite clothing or other
ammable materials.
Keep clothing, furniture, draperies and other
ammable materials away.
HOT SURFACES!
Screen/mesh, glass doors
and other surfaces are hot
during operation AND cool
down.
DO NOT DISCARD THIS MANUAL
CAUTION
Important operating
a n d m a i n t e n a n c e
instructions included.
Leave this manual with
party responsible for
use and operation.
Read, understand
and f o l l o w th e s e
instructions for safe
i n s t a l l a t i o n a n d
operation.
DO NOT
DISCARD
Heatilator • CL36D, CR36D • 12538 • Rev Z 7/12
Vista de página 0
1 2 3 4 5 6 ... 47 48

Resumo do Conteúdo

Página 1 - Owner’s Manual

1Owner’s ManualInstallation and OperationModels:CL36DCR36DWood Burning FireplaceInstallation and service of this  replace should be performed by qual

Página 2 - Congratulations!

10M. Wood FuelHardwood vs SoftwoodYour replace performance depends on the quality of the rewood you use. • Seasoned wood contains about 8,000

Página 3 - User Guide

113 Maintenance and Service Figure 3.1 Chimney & Termination Cap CleaningA. Disposal of AshesFrequency: When they reach bottom of grateBy: Homeow

Página 4 - Limited Warranty

12C. Check Firebox RefractoryFrequency: After each ash removalBy: HomeownerD. Inspect GrateFrequency: After each ash removalBy: HomeownerInspect grate

Página 5 - WARRANTY EXCLUSIONS:

134 Troubleshooting Guide Start Fire Problems Possible Cause SolutionCan’t get re started Excessive smoke or spillage Burns too slowly Smolders, sizz

Página 6 - Listing and Code Approvals

145 Getting Started A. Typical Fireplace SystemInstaller GuideHeatilator • CL36D, CR36D • 12538 • Rev Z 7/12))))))))))))))))))))))))))))))))))))))))))

Página 7

15Negative pressure results from the imbalance of air avail-able for the replace to operate properly. It can be stron-gest in lower levels of the hou

Página 8

16Marginal Location:• Below peakLocation NOT recommended:• Not the highest point of the roof• Wind loading possibleMulti-level RoofsWindward Leewar

Página 9 - L. Clear Space

17Before beginning the installation be sure the following tools and building supplies are available:Reciprocating saw Framing materialPliers Non-com

Página 10 - M. Wood Fuel

186 Framing & Clearances Figure 6.1 Fireplace Locations (Framing dimensions shown)A. Select Fireplace Location23 in. 45 in.48 in. Min. 45 in.23 i

Página 11 - Maintenance and Service

19B. ClearancesWARNING! Risk of Fire! You must comply with all minimum air space clearances to combustibles as specied in Fig-ure 6.2. DO NOT pack re

Página 12 - E. Glass Cleaning

2Read this manual before installing or operating this replace.Please retain this owner’s manual for future reference.Homeowner Reference InformationM

Página 13 - Troubleshooting Guide

2016 3/4 in. Minimum48 in. Min. 36-5/8 in.50 deg20 in.4 in. 39 deg BRICK FRONT 14-1/2 in. 18 in. Min. 48 in. Min. 34 in. 39 deg14-1/2 in.18 in. Min.16

Página 14 - (Section 8)

21D. Frame the FireplaceFigure 6.4 shows typical framing using combustible materials (2x4 lumber shown).• Observe all required air space clearances t

Página 15 - C. Draft

227 Installation of Fireplace CAUTION! Risk of Cuts/Abrasions. Wear protective gloves and safety glasses during installation. Sheet metal edges are sh

Página 16 - Windward

23Outlet placed higher than 3 ft below the termination cap Attic space Garage or combustible liquids storage Outlet blocked by snow, leaves, etc. Clea

Página 17

24Figure 7.5 Outside Air InstallationE. Install Outside Air Kit• Keep duct runs short and straight to minimize restriction. A small dip is acceptabl

Página 18 - Framing & Clearances

25Chimney must extend beyond combustible roof structure Maintain minimum height of chimney above roof Additional support for tall chimneys Install ro

Página 19 - B. Clearances

26A. Chimney RequirementsMeasure vertical distances from the base of the replace as shown in Figure 8.2.20 ft (6.10 m) max.pipe between anoffset &

Página 20 - C. Sidewalls/Surrounds

27Table 8.2B. Using Offsets/Returns• Use an offset/return to bypass overhead obstructions.• An offset and return can be used as a single entity or s

Página 21 - D. Frame the Fireplace

28Figure 8.4 Assembling Chimney SectionsROOM ABOVE (non-insulated ceiling) ATTIC ABOVE (insulated ceiling) B A Ceilng firestop from bottom Ceiling fi

Página 22 - D. Level Fireplace

293 in. (76 mm)overlapInsert three screwsBend inward 90°Bend remaining tabs to rest against pipe to prevent insulation from falling in.Figure 8.6 Pre

Página 23

3 Safety Alert Key:• DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury.• WARNING! Indicates a ha

Página 24 - E. Install Outside Air Kit

30Figure 8.9 Ceiling/Attic ConstructionH. Complete InstallationWARNING! Risk of Fire! You MUST maintain 2 in. (51 mm) air space to insulation and oth

Página 25 - Chimney Assembly

31Slanted RoofsFlat RoofsChimney mustextend 3 ft (.9 m)above the roofChimney must extend 2 ft (.6 m)above any portion of the roof oradjacent structure

Página 26 - Table 8.1

329 Chase Installations CeilingFirestopMetal Chase TopRound Termination CapFalse CeilingInsulation in theoutside wallsof the chaseAttic InsulationShie

Página 27 - B. Using Offsets/Returns

33Slope Downward(1/4 in. per footminimum)Turn-down Drip Edge Chase2 in. (51 mm) Collar on Chase Top .018 (26 ga) min. Galvanized Chase Top Figure 9.3

Página 28 - E. Install Ceiling Firestops

34Heatilator • CL36D, CR36D • 12538 • Rev Z 7/12StormCollarChimneyPipeChase TopTerminationCapChase14 1/2 in. (368 mm)MaximumCollar2 in. (51 mm)Minimum

Página 29

353 in (76 mm)minimumMin.Base Dim.Min.Base Dim.Min. Top Dim.Min. Top Dim.Min. OpeningWidthMin. OpeningWidth3 in. (76 mm) tall legsØ 17 1/2 in. (444.5

Página 30 - G. Cut out Hole in Roof

363 in. (76 mm)Min. Opening HeightMin. Base DimMin. Heightabove radiation shieldMin.Base Dim3 in. (76 mm) Min.Radiation Shield Heightfrom top of Chase

Página 31

3711 Finishing A. Non-combustible Materials• Materials which will not ignite and burn, composed of any combination of the following:- Steel -

Página 32 - Chase Installations

38D. Finishing MaterialRefer to Sections 11.A. and Sections 11.B. for combus-tible/non-combustible materials. Refer to Figure 11.2 for non-combustible

Página 33

39E. Combustible Mantel • Refer to the shaded areas of Figure 11.4 for locations and dimensions of a combustible mantel.• A combustible mantel may b

Página 34

44021-645C 12-29-10 Page 1 of 2Hearth & Home Technologies Inc.LIMITED LIFETIME WARRANTYHearth & Home Technologies Inc., on behalf of its hear

Página 35 - Shrouds

40F. Sidewalls/Surrounds• Adjacent combustible sidewalls must be located a minimum of 18 in. (457 mm) from the fireplace opening.16 3/4

Página 36 - Min. Height

41Firebox RepackinsulationknockoutCombustible materialsMaintain air clearance to combustibles. Gas lineCombustible materials may be located at zero cl

Página 37 - Finishing

4213 Reference Materials A. Fireplace Dimensions8-1/2 in.1-1/2 in. SQ.GASOPENING1-1/2 in. DIA.ELECTRICALKNOCKOUT1/2 in.5-1/4 in.8 in.13-3/4 in.34 in.

Página 38 - D. Finishing Material

43C. Chimney ComponentsThe following pictures show only those chimney components which may be safely used with this replace.ID4 Insulated DuctUD4 Uni

Página 39 - E. Combustible Mantel

44TR-TVKTR Top Vent KitHeatilator • CL36D, CR36D • 12538 • Rev Z 7/12AB14-1/2 in.(368 mm)Ceiling FirestopAssembledDiameter: 14 1/2 in./368 mmHeight: 2

Página 40 - F. Sidewalls/Surrounds

45ABCDLDS33/LDS46 Decorative ShroudEDACBLDS-BV Decorative ShroudCatalog #A B C Din. mm in. mm in. mm in. mmLDS33 36 914 36 914 8.5 216 11 279LDS46 48

Página 41 - Accessories

46D. Service PartsIMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for your appliance please provide model number an

Página 42 - Reference Materials

47D. Service PartsD. Service Parts (continued)CR36D36 in. Right Corner Woodburning FireplacesBeginning Manufacturing Date: Apr 1995 Ending Manufac

Página 43 - C. Chimney Components

48– NOTES –E. Contact InformationDO NOT DISCARD THIS MANUALCAUTION• Important operating a n d m a i n t e n a n c e instructions included.• Leave

Página 44 - (826 mm)

54021-645C 12-29-10 Page 2 of 2WARRANTY CONDITIONS:• This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or

Página 45 - Catalog # A B C E E

61 Listing and Code Approvals NOTICE: This fireplace is tested and approved as a decorative replace. It should not be factored as a primary h

Página 46 - Stocked

72 Operating Instructions WARNING! DO NOT operate  replace before reading and understanding operating instructions. Failure to operate  replace acco

Página 47 - D. Service Parts (continued)

8• The rst three or four res should be of moderate size to allow the oils and binders to be burned from the replace and the refractory and pai

Página 48 - Mt. Pleasant, Iowa 52641

9CORRECTCORRECTINCORRECTFigure 2.2 Operating Positions of Bi-fold Doors WARNING! Risk of Fire and Smoke! Fireplaces equipped with doors should be op

Comentários a estes Manuais

Sem comentários